PILETA Co., Ltd. is a testing laboratory accredited under the Korea Laboratory Accreditation Scheme (KOLAS), Accreditation No. KT921. From request to test report, testing follows a five-step process in line with international standards.

5-Step Process

KOLAS five-step process

From request to test report, accredited testing proceeds in five steps in line with international standards.

  1. Step 1

    Request

    Send your test request by email (pileta@pileta.co.kr) or call us at +82-42-368-0180. Including the test items, sample information and preferred schedule helps us respond faster.

  2. Step 2

    Review and quotation

    The assigned test engineer reviews your request and contacts you by phone or email. Together we review and agree on the test method (applicable standards), specimen requirements, schedule and cost.

  3. Step 3

    Contract

    A contract (purchase order) is concluded on the agreed terms. The test is confirmed when the samples are received.

  4. Step 4

    Testing

    Tests are performed in accordance with KOLAS accreditation procedures and our quality management system. The assigned test engineer keeps you informed of progress.

  5. Step 5

    Test report

    When testing is complete, we issue a KOLAS-accredited test report. KOLAS is a signatory to the ILAC Mutual Recognition Arrangement (ILAC MRA), which facilitates the acceptance of accredited test reports in other signatory economies.

25 Accredited Test Items

KOLAS-accredited test items

PILETA holds KOLAS accreditation for a total of 25 test items and performs demanding tests in-house, including thermomechanical fatigue (TMF), fracture toughness and fatigue crack growth rate (FCGR) testing.

CategoryTest itemCondition / detailsEvaluation
TensileTensile test — room temperatureRoom temperatureUltimate tensile strength (UTS), yield strength (YS) and elongation; quantification of yielding and fracture behavior
TensileTensile test — elevated temperatureElevated temperatureTensile behavior at elevated temperature
TensileTensile test — low temperatureLow temperatureTensile behavior at low temperature
CreepCreep testElevated temperature, long durationLarson–Miller parameter (LMP) and Robinson's life-fraction rule; evaluation of time to strain and rupture
FatigueLow-cycle fatigue (LCF) testFatigue life under cyclic loading
FatigueHigh-cycle fatigue (HCF) testS-N curves
FatigueThermomechanical fatigue (TMF) testAdvancedHigh temperatureCombined thermal and mechanical fatigue
Fracture toughnessKIcAdvancedC(T)/SE(B) specimensPlane-strain fracture toughness
Fracture toughnessJIcAdvancedC(T)/SE(B) specimensElastic-plastic fracture toughness
Fracture toughnessFCGRAdvancedda/dNFatigue crack growth rate
Impact (Charpy)Charpy impact test — room temperatureRoom temperatureAbsorbed energy
Impact (Charpy)Charpy impact test — elevated temperatureElevated temperatureToughness variation with temperature
Impact (Charpy)Charpy impact test — low temperatureLow temperatureTransition temperature analysis
HardnessVickers hardness testHardness measurement
HardnessRockwell hardness testHardness measurement

The table above lists representative items in our accredited testing fields. The complete list of 25 accredited test items and the applicable standards are defined by our KOLAS scope of accreditation (KT921). Details are available on request.

Test Reports & ILAC MRA

Test reports and the ILAC MRA

For accredited tests, PILETA issues KOLAS-accredited test reports. KOLAS is a signatory to the ILAC Mutual Recognition Arrangement (ILAC MRA), which facilitates the acceptance of accredited test reports in other signatory economies. Our accredited test reports can support submissions to overseas clients, licensing and permitting, and reliability verification in the aerospace and defense sectors.

Test reports can be sent by post or email, or collected in person. English-language test reports are available on request.

Turnaround & Quotation

Turnaround time and quotation

Turnaround time depends on the test items, the number of specimens and the test conditions (temperature and load). Creep and fatigue tests in particular take a long time to run, so we provide an estimated schedule at the review and quotation step.

Expedited Testing

If you need expedited testing, please state this in your request. We will confirm availability based on the equipment schedule.

Check Your Request

To check the status of your request, contact the assigned test engineer or email pileta@pileta.co.kr. Requests submitted through the online form on our Korean site can be checked there with the email address or phone number and the password entered at submission.

Ready to get started? Send us your test request.