Deployed for KEPCO at a combined cycle power plant
The system runs unattended, with OPC UA nodes updated every second and hourly automatic CSV backups.

HRSG DAS — Data Acquisition System
Built for heat recovery steam generators (HRSGs), HRSG DAS (HRSG Data Acquisition System) is an industrial data acquisition system with standard TCP/UDP and OPC UA communications, redundant servers for uninterrupted operation and real-time updates every second. Deployed for Korea Electric Power Corporation (KEPCO), it runs unattended at a combined cycle power plant.
Core Features
A single system covers the entire data acquisition chain, from field measurement to external system integration.
Architecture — Data Flow
Raw signals from field sensors go through calculation and batch processing on the server, accumulate in a time-series database, and are delivered simultaneously to a real-time dashboard and an OPC UA client.
NI cRIO-9073
Acquires raw signals from field instruments
TCP / NI 6340
Sends data to the server over standard protocols
Console
Calculation + batch processing
Time-series storage
High-speed data accumulation
Real-time dashboard / CSV
Monitoring · backup output
Parallel output. Collected data is provided simultaneously to the user interface (real-time dashboard / CSV) and the OPC UA client (external integration).
Calculation Module
Key equations of the built-in calculation module that converts raw instrument signals into field engineering units.
4–20 mA → −500 to 500 Pa
Linearly converts the analog current signal from the instrument into pressure in engineering units.
ρ = P / (R · T)
Calculates fluid density from pressure and temperature using the ideal gas equation of state.
V = Cf · √(2ΔP / ρ)
Calculates flow velocity from the pitot tube differential pressure and the density.
Q = V · A · 3600
Converts velocity and cross-sectional area into hourly flow rate.
Why HRSG DAS
Redundant server architecture, demonstrated in unattended system operation.
Vendor-neutral integration with distributed control systems (DCS) and external systems via OPC UA.
Built-in Calculation Module that automatically converts raw instrument signals into field engineering units.
Impact
Field Reference
The system runs unattended, with OPC UA nodes updated every second and hourly automatic CSV backups.
| Item | Specification |
|---|---|
| Communications | Standard TCP / UDP / OPC UA communications |
| Update interval | OPC UA nodes updated every second |
| Backup | Hourly automatic CSV backups |
| Storage | MariaDB time-series database |
| Availability | Redundant servers for uninterrupted operation |
| Integration | External system integration via OPC UA client |
Ready When Reliability Matters
The PILETA Test & Evaluation Center is accredited by the Korea Laboratory Accreditation Scheme (KOLAS) as a testing laboratory (Accreditation No. KT921). From testing and failure analysis to digital solution consultations, our engineers respond to you directly.